condenser piping ?


i think i'm having a brain fart but i don't see whats the purpose of this 3 way valve .

Attached Thumbnails
Click image for larger version Name: untitled.jpg Views: 38 Size: 21.1 KB ID: 249371  
Reply With Quote
Old Today, 10:54 AM
ZeroCool's Avatar

Regular Guest

 

Join Date: Jan 2002

Posts: 207

LOL, I am going out on a limb and say to somehow regulate pressure so that the return from building "B" will be able to overcome building "A"? I could see a lot of issues with that design. I would really have to see the engineers S.O. on that one.

Reply With Quote
Old Today, 11:25 AM

Professional Member*

 

Join Date: Aug 2009

Location: Prattville,Alabama

Posts: 348

What is the load in the buildings? WSHP's? Was the lower building added to the existing upper building? I am curious to see the complete drawings, if possible. And, like ZeroCool said, the sequence of operation probably explains it. Maybe they are using one tower to maintain two loops at different temps. Driving the tower setpoint to maintain the cooler loop and mixing return water to maintain the other loop slightly warmer?

Reply With Quote
Old Today, 11:46 AM

Professional Member

 

Join Date: Apr 2006

Location: mechanical room

Posts: 1,085

Yeah , a bit different from your typical condenser water loop . The whole building is now chopped up . It's got the trane self contained units for the floors with free cooling and lil heat pumps on the same loop throughout building . Pumps stay on 24/7 and the tower fan is now on a drive . I think the bottom loop needs both pumps on to overcome the main building loop . How else woould water flow into the tower header when it's piped off it's return . Still don't get it . I know it'll hit me in a sec.

Reply With Quote
Old Today, 11:48 AM

Professional Member

 

Join Date: Apr 2006

Location: mechanical room

Posts: 1,085

I think the bottom loop was supposed to be used for the hp's and the other for the self contained units

Reply With Quote
Old Today, 08:00 PM

Professional Member*

 

Join Date: Feb 2006

Location: Atlanta,GA.

Posts: 597

dont think ive seen a loop for wshps without a boiler

Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules

You may not post new threads

You may not post replies

You may not post attachments

You may not edit your posts


HTML code is Off


Forum Jump



Go Back   HVAC-Talk: Heating, Air & Refrigeration Discussion > The ARPA Zone/Open General Discussion Forums > Tech to Tech Chat - Commercial


Notices

Tech to Tech Chat - Commercial FOR TECHNICAL CHAT BETWEEN INDUSTRY WORKERS ONLY. NO AOP OR DIY>> This forum is for Technical Chat in the Commercial Industry and only within the limits of the Open area Rules concerning DIY. Any technical chat that goes too far will be removed or moved to the Pro Area.

Reply

0 comments:

Post a Comment